AuditLok XLV Communication

V1C/V2C Device Search

Perform a Device Search to establish C-unit internal soft addresses and internal device inventory. A Device Search must be done after replacing the CPU, a UIB or a Lock Board (rather than replacing an entire can supplied by the factory) or if the CPU is not communicating with or otherwise not recognizing its internal device inventory. The Device Search establishes communication between the CPU and all boards inside the C-unit.
1. Print End Day, Enrolled User, and Configuration reports if possible.
2. Disconnect all R-units from the data bus (primary display EPR must remain connected).
3. Remove power from the C-unit safe.
4. On the first Lock Board set SW1 Segment 1 to ON.
5. On the second Lock Board (if present) set SW1 Segments 1 and 6 to ON.
6. On the last Lock Board in the circuit (J1 or J2 will be open) set SW1 Segment 8 to ON.
7. On UIBs set SW2 Segment 8 to ON (Segment 1 must also be ON for JCM validators only).
8. Restore power.
9. Perform a “52” override (requires phone contact with NKL Technical Service: 1.800.452.4655).
10. Wait at least one full minute after the Device Search is complete.
11. Remove power.
12. Set Lock Board SW1 Segment 1 to OFF (all Lock Boards).
13. Set UIB SW2 Segment 8 to OFF (all UIBs).
14. Restore power. Wait at least one full minute (until the CPU full initializes) before continuing.
15. Check the inventory. Repeat this procedure if all boards in the C-unit are not found.
16. Reconnect R-units.

D8C Device Search

Perform a Device Search if the physical inventory of C-unit boards does not match the virtual inventory (Section 9). This normally happens after replacing one or more boards in the C-unit when all boards are not replaced as a pre-configured kit (can, main vend board and outer door lock board) from the factory. Check the device inventory via diagnostic screen. A D8C should indicate one vend board and one or two lock boards (two lock boards if the D8C has an inner door). The Device Search establishes communication between the CPU and all boards inside the C-unit.
NOTE: Set the D8C outer door lock board SW1 Segment 8 set to ON to terminate the internal data bus. If the D8C has a built-in display, a jumper (part 15187001) should be installed at SW1 on the back of the display board.
1. Print End Day, Enrolled User, and Configuration reports if possible.
2. Disconnect all R-units from the data bus.
3. Remove power from the C-unit safe.
4. Set Inner Door Lock Board SW1 Segment 1 to ON, all other segments OFF (this step is only required if the CPU or Inner Door Lock Board are replaced).
5. Set Outer Door Lock Board SW1 Segments 1, 6 and 8 to ON, all other segments OFF.
6. Set Vend Board SW1 Segment 8 to ON, all other segments OFF.
7. Restore power to the safe.
8. Perform a “52” override (requires phone contact with NKL Technical Service: 1.800.452.4655).
9. Wait at least one full minute after the Device Search is complete.
10. Remove power from the safe.
11. Set Inner Door Lock Board SW1 Segment 1 to OFF (if set to ON in step 5).
12. Set Outer Door Lock Board SW1 Segment 1 to OFF.
13. Set Vend Board SW1 Segment 8 to OFF.
14. Restore power to the safe. Wait at least one full minute (until the CPU full initializes) before continuing.
15. Check the inventory. Repeat this procedure if all boards in the C-unit are not found.
16. Reconnect R-units.

Max Vend Device Search

Perform a Device Search if Max Vend inventory does not include one Lock Board and one UIB (Section 9). This may happens after replacing the UIB or Lock Board if all boards are not replaced as a pre-configured kit from the factory. Check the device inventory via diagnostic screen. Max Vend should indicate one Lock Board and one UIB. The Device Search establishes communication between the CPU and the UIB and Lock Board inside the C-unit. The Hopper Board is not subject to the Device Search.
1. Print End Day, Enrolled User, and Configuration reports if possible.
2. Disconnect all R-units from the data bus.
3. Remove power from the safe.
4. Set Lock Board SW1 Segment 1 and 8 to ON.
5. On the UIB set SW2 Segment 8 to ON.
6. Restore power to the safe.
7. Perform a “52” override (requires phone contact with NKL Technical Service: 1.800.452.4655).
8. Wait at least one full minute after the Device Search is complete.
9. Remove power from the safe.
10. Set Lock Board SW1 Segment 1 to OFF.
11. Set UIB SW2 Segment 8 to OFF.
12. Restore power to the safe. Wait at least one full minute (until the CPU full initializes) before continuing.
13. Recheck the inventory. Repeat this procedure if the UIB and/or Lock board are not found.
14. Reconnect R-units.