OperationD8X Only D8C Vend/Load/Unload Drops & Buy Change Door Operation Reports Add/Remove Users Communication Rules Diagnostic Screen Add Devices Remove Devices Device Search Device Sync Lantronix Setup Configuring Definitions Naming Things Clock Store Info Printing Options User Options D8C Vend Max Vend Locks Cash Service Error Messages Max Vend Electrical D8C Electrical V1/V2 Electrical Power Lock Systems D8C Vend Assembly D8X Vend Assembly Hopper System MEI 3900 Validators CashCode Validators JCM Validators Parts Lists Max Vend V1/V2 D8C D8X |
AuditLok XLV CommunicationAbout Removing DevicesBefore taking any action that involves or requires removing a V1R or V2R, run all necessary financial reports and in particular a Cash Report if possible. When the CPU is to be replaced, all R-units must be removed first, if possible. If that is not possible the R-units must be removed by factory override after the CPU is replaced. When electronics are replaced in an R-unit, that R-unit must be removed (from C-unit inventory) before attempting to add the replacement electronics. R-units must have power when being removed regardless of the means.Remove Device (V1R/V2R) ProcedureThe V1R and V2R-units being removed must be connected to the C-unit via data bus for it to receive the Remove Device command.1. Log In. 2. Press PGRM. 3. Select DEVICES. 4. Select the V1R or V2R to be removed. 5. Select REMOVE. 6. The selected R-unit is no longer in the inventory of the C-unit. If it was properly connected and communicating at the time, it received the Remove Device command and is now available to be added to a C-unit. The data bus should be disconnected after all devices are removed. Remove DisplaySince EPRs have no configurable settings they do not appear on the DEVICE menu. Use this procedure to remove an EPR from the C-unit inventory and, if it is connected to the C-unit at the time, its Display Address is reset to 00.1. Log In. 2. Press PGRM. 3. Select DISPLAYS. 4. Select the display to be removed (Display 00 cannot be removed). 5. The selected display is no longer in the inventory of the C-unit. If it was properly connected and communicating at the time, it received the Remove Device command and is now available to be added to a C-unit. The data bus must be disconnected immediately after removing the display to avoid serious communication problems (you may remove power from the display if the data bus cannot be broken at this time). Override to Remove Device (R-Unit or Display)The V1R, V2R or EPR units being removed must be connected to the C-unit via data bus for it to receive the Remove Device command. For additional information about overrides refer to Section 10.1. Perform the "50" override. 2. After the override is complete, disconnect the data bus to all R-units (do not disconnect Display 00 if it is mounted in an EPR case). Manually Reset Display AddressReset the software address of a Display manually if it is the only display (Display 00) and it will not respond; reset an auxiliary display if you are attempting to add it and it will not respond to the Add Device procedure (it should be removed from Display inventory before attempting to add it back in).1. Remove the security screws holding the display to the safe front panel or EPR box. 2. If the display is built into the header disconnect the RJ45 cable from the can or if the display is in an EPR remove power from the EPR. 3. Press and hold down the reset button on the display circuit board. 4. Reconnect the display (RJ45 if header mounted or power if EPR mounted). 5. After 30 seconds release the reset button. 6. Cycle power to the display and test operation. If it is an auxiliary display it may now be added. |
|
Copyright
©2009 Updated 4-16-09 |
||