Add Device Procedure

When a system includes one or more R-units there are times during the course of service, such as after certain electronics are replaced, when it is necessary to add an R-unit (or EPR) to the C-unit. Establish communication with a V1R, V2R, or EPR as follows:
1. All components must be powered. The data bus is not connected to the R-unit(s) to be added until directed.
2. Log In.
3. Press PGRM.
4. Select DEVICES.
5. Select ADD.
6. While the screen indicates ADD DEVICE NOW connect the data bus from the D8C (DATA OUT) to the first R-unit (DATA IN).
7. If the system has one or more R-units already connected and communicating, connect the data bus from the last R-unit already connected (DATA OUT) to the next R-unit (DATA IN).
8. Connect the Terminator Plug to the DATA END port on the last R-unit on the data bus (furthest from the D8C on the data bus).
Note: The DATA END jack does not exist on R-units built prior to serial number SP2008032034. On older R-units the termination plug is not required unless R-unit electronics are replaced.