Tech Browser Topics Essential XL FireKing PDF Library Garda Autobank XLViP
 
Operation
Login
Change PIN
Open Doors
Manage Users
Audit Report
Config Report

Configuration
Daylight Savings
System Clock
Door Setup
Delay & Timelock
Lockout Schedule
Idle Text
PIN Parameters

Service
Installation
Error Messages
Alarm Sounding
Alarm Wiring
Electronic Parts
Chassis Parts
Overrides
AuditLok XL 2008 - Overrides

Types of Overrides

00 - LOST KEY User's Personal ID and PIN must be known. After running this override, the user may enter their 9-digit personal ID in place of their electronic key. This will work for 12 hours.
01 - EDIT USER Allows access to change status of any user (Delete, Inactivate, or Temp PIN). EXAMPLE SCREEN.
02 - ENROLL KEY Enroll a new key into the safe. EXAMPLE SCREEN.
03 - DATE Change the system date. EXAMPLE SCREEN.
04 - TIME Change the system time. EXAMPLE SCREEN.
05 - IDLE TEXT Change the name of the business at the idle screen. EXAMPLE SCREEN.
06 - COMPANY CODE Immediately deletes all users. All keys must match the new company code to be enrolled. EXAMPLE SCREEN.
07 - DOOR CONFIGURATION Set Behind, Dual, Exists, and Sensors options. EXAMPLE SCREEN.
10 - PIN PARAMETERS Set PIN Life, Auto-Inactive, and Auto-Delete features. EXAMPLE SCREEN.
11 - BREAK TIMELOCK Timelock and delay settings disabled for 12 hours.
12 - DELAY/TIMELOCK Set door Delay, Access, Alarm, and Timelock settings. EXAMPLE SCREEN.

Procedure

1. Press "0/ESC" twice (once to wake up the screen and once to access the ESC Menu).
2. Select "OVERRIDES".
3. Enter the the correct OVERRIDE TYPE (listed above).
4. Select "DONE".
5. The screen will show a 5-digit number. Enter this number in the override generator then enter the response number from the generator into the safe.
6. Select "DONE".
7. Follow directions on the screen (depends on type of override performed).
Copyright ©2009
Updated 4-24-09