Tech Browser Topics Essential XL FireKing PDF Library Garda Autobank XLViP
 
Operation
Login
Change PIN
Open Doors
Manage Users
Audit Report
Config Report

Configuration
Daylight Savings
System Clock
Door Setup
Delay & Timelock
Lockout Schedule
Idle Text
PIN Parameters

Service
Installation
Error Messages
Alarm Sounding
Alarm Wiring
Electronic Parts
Chassis Parts
Overrides
AuditLok XL 2008 - Delay & Timelock

Admin Login
Select SUPERVISORY.

Supervisory Menu
Select DOORS.

Door Configuration
Scroll to the desired DOOR then select setting to edit.

Delay

To disable the door delay set the value to 00. Delay value is set in minutes (00 to 99). When a delay is set, users must log in once to start the delay then log in again during the access period (after the delay ends) to open the door.
Administrator Only:
1. Log in.
2. Select “SUPERVISORY”.
3. Select “DOORS”.
4. Scroll left or right as needed to select the door to setup.
5. Select “DELAY”.
6. Enter the desired Delay value using the number pad.

Access

The Access value is set in minutes (00 to 99). The default value is 05. Access time is the period following a door delay during which a user may log in the second time to open the door.
Administrator Only:
1. Log in.
2. Select “SUPERVISORY”.
3. Select “DOORS”.
4. Scroll left or right as needed to select the door to setup.
5. Select “ACCESS”.
6. Enter the desired Access value using the number pad.

Alarm

Alarm value is set in minutes (00 to 99). The default value is 05. Alarm time begins to count as soon as a door opens. If the door remains open after the Alarm time expires, the safe will sound an audible alarm and a violation is logged in the audit.
Administrator Only:
1. Log in.
2. Select “SUPERVISORY”.
3. Select “DOORS”.
4. Scroll left or right as needed to select the door to setup.
5. Select “ALARM”.
6. Enter the desired Alarm value using the number pad.

Timelock

Timelocks are set in military time. Up to two timelock windows may be used, although when one is set there is no need to set a second unless two seperate windows are required. Each day of the week may be configured separately or all days may be set from one screen. The safe comes out of timelock at the UNL time and goes into timelock at the LCK time. Set both times to 00:00 to disable. Set both to 01:00 to put into permanent timelock (access via Armored Car e-key only).
Administrator Only:
1. Log in.
2. Select “SUPERVISORY”.
3. Select “DOORS”.
4. Scroll left or right as needed to select the door to setup.
5. Select “TIMELOCK”.
6. Select the desired day of the week to set or cycle to ALL to set all days at once.
7. Select the first row of UNL and LCK times, then enter the times desired. Repeat for the second row only if a second window is required otherwise the second row should be set to 00:00 (both values).
8. Select "DONE".


Timelock
Copyright ©2009
Updated 4-21-09