Tech Browser Topics Essential XL FireKing PDF Library Garda Autobank XLViP
 
Operation
Log In
Print Audit
External Security Doors
Doors
Manage Users

Configuration
Daylight Savings

Delay & Timelock
Factory Key
Key Chart

Service
Installation
Error Messages
Alarm Problem
Key Problem
Power Problem
Printing Problem
Alarm Wiring
Electronics Parts
Chassis Parts
Overrides
Upgrade Policy

OLD AuditLok XL - Overrides

Types of Overrides

00 - LOST KEY User's Personal ID and PIN must be known. After running this override, the user may enter their 9-digit personal ID in place of their electronic key. This will work for 12 hours.
01 - EDIT USER Allows access to change status of any user (Delete, Inactivate, or Temp PIN). EXAMPLE SCREEN.
02 - ENROLL KEY Enroll a new key into the safe. EXAMPLE SCREEN.
03 - DATE Change the system date. EXAMPLE SCREEN.
04 - TIME Change the system time. EXAMPLE SCREEN.
05 - IDLE TEXT Change the name of the business at the idle screen. EXAMPLE SCREEN.
06 - COMPANY CODE Immediately deletes all users. All keys must match the new company code to be enrolled. EXAMPLE SCREEN.
07 - DOOR CONFIGURATION Set Behind, Dual, Exists, and Sensors options. EXAMPLE SCREEN.
10 - PIN PARAMETERS Set PIN Life, Auto-Inactive, and Auto-Delete features. EXAMPLE SCREEN.
11 - BREAK TIMELOCK Timelock and delay settings disabled for 12 hours.
12 - DELAY/TIMELOCK Set door Delay, Access, Alarm, and Timelock settings. EXAMPLE SCREEN.

Procedure

1. STANDARD XL: Press 1 and 4 simultaneously until COMPANY and SERIAL numbers appear on the screen. Make sure no asterisks (* symbol) appear on the screen yet.
2.
KEYLESS/BIO XL: Press the bottom left scroll button twice. COMPANY and SERIAL numbers will appear on the screen.
3. Enter the PIN 0000.
4. Enter the USER ID 888888888 and select DONE.
5. A 9-digit safe code will be displayed in the lower-left portion of the display. Use this code to generate the override code.
6. Allow the screen to go to screen saver mode or press the LEFT scroll button to immediate begin entering the override code.
7. Enter the 9-digit response code. Pay no attention to the screen while entering the override number.
WARNING: Once you begin entering the response code any pause of more than 7 seconds will exit you to the screen saver mode and you will have to begin again from step 1.
8. After correctly entering the last digit of the sequence the display will read FACTORY LOST KEY, PLEASE ENTER PIN. If the display reads anything different, press the arrow key in the upper right corner and repeat Step 7. If this happens twice, start over at Step 1.
9. Enter the PIN 0000.
10. Follow directions on the screen.
Copyright ©2009