OLD AuditLok XL - Error Messages

INVALID USER

The user is not enroll, was deleted, or the key is damaged.

KEY INACTIVE SEE MANAGER

The user is inactive. A Manager or Administrator level user may change the user's status to Active. See Managing Users.

PIN EXPIRED ENTER NEW PIN

The user has never logged in before or their PIN Life period is up and they are required to change their PIN. See Change PIN.

BATTERY LOW

Low voltage to the system. The most likely cause is that the electronics are running on the internal battery backup which is running low. Batteries were discontinued in 2000.

ELECTRONICS ERROR

1. Unplug the transformer.
2. Remove the outer panel and temporarily disconnect the battery backup.
3. Reconnect the battery and transformer power.
4. If the problem persists the inner board must be replaced. If necessary to drill, replace the lock and lock cable as well.

VIOLATION CHOSE DOOR

1. Close the outer door.
2. If the door is closed, open the outer door and firmly shut it again.
3. If the problem persists, disable the door sensor using a factory override.
4. Replace the door sensor.
5. Re-enable the door sensor via override.