OperationLog In Print Audit External Security Doors Doors Manage Users Configuration Daylight Savings Delay & Timelock Factory Key Key Chart Service Installation Error Messages Alarm Problem Key Problem Power Problem Printing Problem Alarm Wiring Electronics Parts Chassis Parts Overrides Upgrade Policy |
AuditLok XL - Alarm WiringStandard Alarm Output WiringAuditLok XL provides for duress and burglar alarm connections through a cable located at the back of the safe. Each alarm is switched via a SPDT relay with both normally open and normally closed contacts provided. When an alarm condition is activated, the appropriate relay will switch and remain in the alarm state until a valid key and PIN are presented. Bare terminations from the alarm cable are labeled as follows:• Burglar Common (blue*) • Burglar Normally Open (green) • Burglar Normally Closed (yellow) • Duress Normally Closed (black) • Duress Normally Open (red) • Duress Common (white) Wire colors may vary depending on when the safe was manufactured. Relay contact specifications are for 30 VAC/DC, 1A, power limited circuits only. |
|