The TimeLok XL has two types of combinations. To the average operator they are simply inner and outer door combos. This is because to open the outer door 6 digits are used and to open the inner door an additional two digits are used. Actually, this is an eight digit combo broken into two parts. This is a Type 2 combo. A Type 1 combo is only six digits and can only be used to open the outer door. The complete Type 2 combination opens both doors and can also be used to change both combo Types. Ultimately, most safe operators never know the distinction and the difference is not relavent to operation.

Change Combos - Standard Procedure

1. Ensure all doors are closed.
2. Timelock status does not matter.
3. Enter six-digit combo.
4. Observe DOOR 1 light comes on and wait for the DOOR 1 light to go off.
5. Press *.
6. Enter the two-digit inner door combo.
7. Enter the two-digit inner door combo again.
8. Observe the DOOR 1 and MAINTENANCE lights on.
9. If the display reads
C1 go to Step 10, otherwise press *.
10. If the display reads
C1 go to Step 10, otherwise press * a second time. If the display does not read C1 wait 30 seconds and start over.
11. When the display reads
C1 enter the new six-digit combo.
12. When the display reads
C1= enter the new six-digit combo again to confirm.
13. When the display reads
C2 enter the new eight-digit combo (same six-digits, plus two digits for inner door).
14. When the display reads
C2= enter the new eight-digit combo again to confirm.
15. Display will flash
8888 for up to 30 seconds, then the display will return to normal.

Change Combos - Override Procedure

1. Ensure all doors are closed.
2. Timelock status does not matter.
3. Enter the Type 3 Override (see chart below).
4. Press **.
5. The display should read
C1. If not, start over using the next override code in sequence.
6. When the display reads
C1 enter the new six-digit combo.
7. When the display reads
C1= enter the new six-digit combo again to confirm.
8. When the display reads
C2 enter the new eight-digit combo (same six-digits, plus two digits for inner door).
9. When the display reads
C2= enter the new eight-digit combo again to confirm.
10. Display will flash
8888 for up to 30 seconds, then the display will return to normal.

Initialize System

1. A valid Type 2 Combo (eight-digit/inner door) must be used in this procedure. If no combo has been set: generate initial combo via override (above).
2. Enter six-digit outer door combo.
3. If the Door 1 light was already on skip to Step 5, otherwise observe Door 1 light come on.
4. Wait for the Door 1 light to go off.
5. Enter **.
6. Enter the Type 4 Override (see below).
7. The display should read
ClOC and the Maintenance light should be on. If not, go back to Step 2.
8. Enter 0001.
9. The display will read
0=UL. Enter 0003.
10. The display will read
0=L. Enter 2300.
11. The display will read
11UL. Enter 0003.
12. The display will read
11L. Enter 2300.
13. The display will read
12UL. Enter 0003.
14. The display will read
12L. Enter 2300.
15. The display will read
dL00. Press *.
16. Wait for the display to read
0003. Observe all lights go off.
17. Perform the System Setup below.

Setup System

1. System must be initialized and a Type 2 Combo must be set. All time settings are in military time format.
2. Enter six-digit outer door combo.
3. Observe Door 1 light come on.
4. Wait for Door 1 light to go off.
5. Enter **.
6. Enter the Type 4 Override. See below.
7. The display should read
ClOC and the Maintenance light should be on. If not, go back to Step 2.
8. Enter the current time.
9. Note: Pressing * for any of the following will bypass the setting and leave it unchanged.
10. The display will read
O=UL. Enter the outer door unlock time (usually 0002 for 24 hour access).
11. The display will read
O=L. Enter the outer door lock time (usually 0001 for 24 hour access).
12. The display will read
11UL. Enter the inner door first timelock unlock time (0800 is typical).
13. The display will read
11L. Enter the inner door first timelock lock time (1000 is typical).
14. The display will read
12UL. Enter the inner door second timelock unlock time (0800 is typical; set same as Step 12 if only one timelock window is used).
15. The display will read
12L. Enter the inner door second timelock lock time (1000 is typical; set same as Step 13 if only one timelock window is used).
16. The display will read
dL00. This is the inner door delay time. Press the "1" button once for each minute of delay time you want to have and press * when desired value is shown, or press * to leave unchanged.

Break Timelock

1. A valid Type 2 Combo (eight-digit/inner door) must be used in this procedure. The time lock time settings must also be known.
2. Enter six-digit outer door combo.
3. Observe Door 1 light come on.
4. Wait for Door 1 light to go off.
5. Enter **.
6. Enter the Type 4 Override (see below).
7. If the display does not read
ClOC go back to Step 2. The Maintenance light should be on.
8. Enter a time of one minute before the time lock unlock time in military format.
9. The display will read
O=UL. Press * to leave unchanged.
10. The display will read
O=L. Press * to leave unchanged.
11. The display will read
11UL. Press * to leave unchanged.
12. The display will read
11L. Press * to leave unchanged.
13. The display will read
12UL. Press * to leave unchanged.
14. The display will read
12L. Press * to leave unchanged.
15. The display will read
dL00. Press * to leave unchanged.
16. The display should show the time entered in Step 8.
17. Wait until the Timelock light goes off. If it does not go off at the unlock time, go back to Step 2.
18. DO NOT OPEN DOORS AT THIS TIME.
19. Repeat Steps 2 through 16, except use the actual time in Step 8. Failure to do this correctly will result in waiting 5 minutes for the safe to complete its access time.
20. Open doors as needed.
Note: This procedure leaves the safe out of timelock until it cycles into timelock the following day.

Override Codes

Call NKL Technical Service for assistance with performing overrides on this product: 800.452.4655.

Parts List

Part #
Description
T-15131200 Outer Board (was Y-45155)
T-15131100 Inner Board (was Y-45154)
T-15020700 Communication Cable (was Y-45151)
T-15000223 (was Y-45204) Transformer: 9Vdc (Requires Y-16001/15131360 Mouser Cable)
T-15000010 Transformer: 9Vdc (Started in 2000, Requires special mouser cable: contact PARTS dept.)
T-15131360 Power Cable (was Mouser Y-16001)
T-15011000 Inner Door Lock, Knoblock 3100 LaGard [Y-L KIT includes 15011000 & 15014000]
T-15014000 Inner Door Lock Cable, 18"
T-15016000 Outer Door Lock, Swingbolt RS/LH (most doors)
T-15016000 Outer Door Lock, Swingbolt LS/RH (hinges on left version)
T-15014002 Outer Door Lock Cable, 42"