Tech Browser Topics Essential XL FireKing PDF Library Garda Autobank XLViP
 
Easy 120
Specs
Installation
Operation
Theory
Delay Settings
Wiring Service
Main Board Service
Front Panel Service
Power Service
Vending System Service
Door Service
Manual Drop Service
Parts

Easy 120V / 120A
Specs
Installation
Operation
Theory
Programming
Wiring Service
Main Board Service
Front Panel Service
Power Service
Vending System Service
Validated Drop Service
Manual Drop Service
Door Service
Parts

Smart Series
Common Rules
Audit
Manage Users
Open Door
Vending
Drops
Reports
Clock Setup
Door Setup
Vend Setup
Validator Setup
Location Setup
Troubleshooting
Keypad Replacement
Parts List
McGunn Easy 120V / 120A - Programming

About Users

• The Master User (00) has a 6-digit PIN. This code is used for programming and running reports only.
• Users #01 to #10 have a 4-digit PIN and may: vend tubes, check the balance in vend, make validated drops, run reports and open the door.
• Users #11 to #99 have a 4-digit PIN and may: vend tubes, check the balance in vend, make validated drops, and run reports.

Master User PIN

The factory default Master User PIN code is 111111 and should be changed immediately following installation. This code may be changed at any time but cannot be eliminated. If you lose this code, contact McGunn Technical Service for assistance with recovering it.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select MASTER PIN (F1).
• Enter your current Master User PIN and press the ENTER button.
• Enter your new Master User PIN and press the ENTER button.

Add/Delete Users 01 - 99

• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select USER PIN (F3).
• Enter a USER NUMBER then select ADD (F1) or DELETE (F2).
• If you chose to ADD: Assign a 4-digit PIN code and press the ENTER button. You cannot assign the same PIN code to more than one user. If you select a user who is already enrolled this effectively changes the User’s PIN code.

Unit ID

This is a four digit number and it prints on all reports. “Unit” refers to the store number.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select PROGRAM UNIT (F2).
• Enter your unit number and press the ENTER button.

Column Values

Use this procedure to set the “per tube” value for each column.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select COLUMN VALUES (F4, F1).
• Select the column to set and press the ENTER button.
• Enter the new value and press the ENTER button. Repeat these last two steps as needed.

Vend Delay

The vend delay is the delay period following a vend you must satisfy before you may vend again. The purpose of a vend delay is to minimize financial loss during an armed robbery.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select VEND DELAY (F4, F2).
• Enter the desired vend delay value (in minutes) and press the ENTER button.

Vend Threshold

The Vend Threshold limits the maximum dollar amount any one user may vend in a specified period. You define the amount and the period.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select VEND THRESHOLD (F4, F3).
• Enter your desired dollar limit and press the ENTER button.
• Enter the time period (in minutes) and press the ENTER button.

Door Delay

The door delay is the delay period you must satisfy before opening a door (see also DOOR OPERATION – NORMAL above). Door delays are intended help protect against loss of money and life from an armed robbery.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select DOOR DELAY (F4, F4, F1).
• Enter the desired door delay value (in minutes) and press the ENTER button.

Zero Vend Balance

Use this procedure to reset all column totals to zero.
• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select ZERO SYSTEM (F4, F4, F2).
• Press F1 to verify system tube count reset to zero.

Clock

• Enter User Number 00, press ENTER.
• Enter your 6-digit PIN, press ENTER.
• Select YES (F1) to PROGRAM SAFE?
• Select DATE AND TIME (F4, F4, F3).
• Select TIME (F1) and enter the correct time as directed.
• Select DATE (F2) and enter the year, month and day as directed.
Copyright ©2009