McGunn Easy 120 - Delays

Door and Vend Delay Setting

On the main circuit board you will find an eight segment DIP switch marked S2. This DIP switch is used to adjust the DOOR DELAY and VEND DELAY values.
Default Values: By factory default it is configured with segments 2, 4, and 6 ON and all other segments OFF. This combination sets a 10 minute DOOR DELAY with a 2 minute VEND DELAY.
Custom Values: Delays are in units of minutes. With power off change the DIP switches to obtain the desired delay values. Turn power on and the electronics will recognize the new delay settings.

S2 Shown With Default Settings: