Auditor Autobank - Operation

Door Access with Door Key

The vending door is Door 1. The validator door is Door 3. In rare cases other doors may be present. If so, they may use special procedures. Refer to documentation accompanying safe. Doors may be opened using the normal door procedures, ACO procedures, ACO/DOOR Dual Key Override procedure, or may be "slammed" open using a factory override
1. Turn ON/STANDBY key switch to ON (if the safe is equipped with this key switch).
2. Press DOORS. (On some older safes the button may be labeled START DOOR TIMER).
3. Enter a valid USER NUMBER and press ENTER. (Versions older than 2.2 do not use USER NUMBERS).
4. Enter a valid PIN number for the specified USER NUMBER and press ENTER.
5. Enter the door number you wish to open and press ENTER.
6. Choose whether to REMOVE CASH.
7. After the delay is complete the safe will make a distinct chirping sound.
8. Versions 4.0 and lower skip down to Step 13.
9. Press DOORS.
10. Enter a valid USER NUMBER and press ENTER.
11. Enter a valid PIN number and press ENTER.
12. Enter the door number you wish to open and press ENTER.
13. Turn the DOOR key and release.
14. Turn the handle and open the door.

Door Access with ACO Key

Note: Software 5.0 allows up to 13 tubes while Software 5.5 allows only a maximum of 10 tubes.
1. Turn ON/STANDBY key switch (if present) to ON.
2. Press DOORS. (On some older safes the button may be labeled START DOOR TIMER).
3. Enter a valid USER NUMBER and press ENTER. (Versions older than 2.2 do not use USER NUMBERS).
4. Enter a valid PIN number for the specified USER NUMBER and press ENTER.
5. Enter the door number you wish to open and press ENTER.
6. Choose whether to REMOVE CASH.
7. Turn the ACO key and release.
8. Turn the handle and open the door.

Dual Key Override

Store personnel should not be shown how to do this and if they are, they are to be warned NOT to use this procedure for opening the door under normal circumstances.
1. This procedure only applies to Door 1.
2. This procedure will not allow you to zero your drops because it does not allow you to select removing cash.
3. This procedure does not allow the safe to record who entered the safe.
4. Turn the ON/STANDBY key switch (if present) to ON.
5. Simultaneously turn the DOOR key switch, the ACO key switch, and turn the handle to open the door.
6. If the keys are both held turned for more than a few seconds, or if this procedure is performed frequently, it can result in lock failure. The normal failure mode leaves the safe unlocked due to the solenoid seizing in the energized position. If this happens replace the lock.