Auditor Autobank - Door Slam Override

Determine Version

Verify the Software Version to Determine Procedure.
1. To do this either turn power off and back on and observe display, or press DISPLAY several times in quick succession until AUDITOR V[x] is displayed.
2. If power cycling to determine version, the safe should display ROM STARTUP and CHECKING FLASH CODE, then display will say AUDITOR V[x].
3. Either way, the value of "x" determines which of the following procedures to use.
4. If the safe says something different, such as simply ALLIED GARY or similar instead of AUDITOR V[x], use the IQ procedure.

WARNING:
NEVER perform 99 Resets on Software 2.5 or higher unless the configuration data is corrupted or a new CPU board is being installed.

Door Slam Version 2.2 and Above

This procedure works for either door. The purpose is to allow immediate access to open a safe door without a delay and without the use of keys.
1. Press DOORS (on some older safes the button is marked START DOOR TIMER).
2. For USER NUMBER press 0, then press ENTER.
3. A 10-digit number will appear on the display. The factory will use this number to generate a slam code.
4. Obtain and enter the factory generated 10-digit slam code, then press ENTER.
5. When prompted for USER NUMBER, enter a valid USER NUMBER that has access authorization for the door and press ENTER.
6. When prompted for PIN, enter the PIN corresponding to the USER NUMBER in Step 5, then press ENTER.
7. Select the door to open and press ENTER.
8. Select whether to remove cash and press ENTER.
9.
The lock will be energized for only a couple of seconds. The door handle must be turned immediately.
10. After an override cycle is completed the power to the safe must be cycled to clear the override.

Door Slam Version 1.95 and Below

This procedure works for either door. The purpose is to allow immediate access to open a safe door without a delay and without the use of keys.
1. Turn power off.
2. Hold down the PROGRAM and the number 2 on the keypad while turning power on. Keep holding these two buttons until a 10-digit number appears on the display.
3. Release the buttons when the 10-digit number appears on the screen. If more than 10 digits appear, repeat Steps 1 and 2. The factory will use this number to generate a slam code.
4. Obtain and enter the factory generated 10-digit slam code, then press ENTER.
5. When prompted for PIN, enter a valid PIN that has access authorization for the door and press ENTER.
6. Select the door to open and press ENTER.
7. Select whether to remove cash and press ENTER.
8.
The lock will be energized for only a couple of seconds. The door handle must be turned immediately.
9. After an override cycle is completed the power to the safe must be cycled to clear the override.