27 Series Autobank - Operation

Open Door

1. Turn the ON/STANDBY switch to ON.
2. Turn DOOR key until "1000" flashes on screen. This starts a 10 minute delay.
3. After delay completes there will be an audible click when the door unlocks.
4. Turn the door handle to unlock the door and pull the door open.
5. Safes having an ACO key, simply turning the ACO key will immediately unlock the door so that the handle may be turned and the door may be pulled open.

Load Tubes

1. Remove the internal blocking bar or turn the tube lock key, if equipped, so that the tube holes are accessable.
2. Insert money tubes with caps facing out. Ensure caps are firmly on tubes. Never insert tubes through top of chute in the back of the door.

Vend Tubes

1. Turn the ON/STANDBY switch to ON.
2. Check green VEND light on. If not, wait for light to come on. Note: the normal vending delay time is two minutes, but may be as much as 15 minutes or there may be no delay.
3. Press the button over the column you wish to vend from.
4. Retrieve the tube from the vending tray.

Unload (Dump) Tubes

1. Turn the ON/STANDBY switch to ON.
2. Follow the procedures to open the door. Note: If the ACO key is used, you must still wait for the 10 minute delay to complete. It makes no difference whether the door is actually open when unloading.
3. When door delay is complete the safe has a 10 minute access time. Once this 10 minute access time is in progress, press the button for the desired column and it will unload the entire column.


Keypad Closeup