Tech Browser Topics Essential XL FireKing PDF Library Garda Autobank XLViP
 
LpLocks
S&G 6120/6123
LaGard 3600/33E
SmartGard
DigiGard
Keypad Lock - S & G 6120 Series

Normal Operation

1. Enter the 6-digit Combo.
2. Press #.
3. The motor should pull the bolt back to unlock the door.

Change Master Code

1. Press 74.
2. Press *.
3. Enter the existing six-digit Master Code.
4. Press #1*.
5. Enter the new six-digit Master Code.
6. Press #.
7. Enter the new six-digit Master Code again.
8. Press #. The lock will emit 3 disticnt chirps if the new code is accepted. If a long tone is heard the code is not accepted.

Add/Change a User Code

1. Press 74.
2. Press *.
3. Enter the six-digit Master Code.
4. Press #.
5. Enter the user number (2 through 9).
6. Press *.
7. Enter the new six-digit user code.
8. Press #.
9. Enter the new six-digit user code again.
10. Press #. The lock will emit 3 disticnt chirps if the new code is accepted. If a long tone is heard the code is not accepted.

Delete a User Code

1. Press 74.
2. Press *.
3. Enter the six-digit Master Code.
4. Press #.
5. Enter the user number (2 through 9).
6. Press *##. The lock will emit 3 disticnt chirps to indicate the user is deleted.

Lock Won't Open

1. Replace the batteries. Make sure to use good quality alkaline batteries.
2. If the lock solenoid still does not pull back and the keypad appears to operate correctly try placing the batteries in series (18 Vdc). Otherwise replace the keypad.
3. Drill and replace the lock.

 
S&G Keypad
S&G Keypad: Front
S&G Keypad - Where to Install Batteries
S&G Keypad: Batteries Install in Back
Copyright ©2009
Updated 4-24-09