XLV-iP CT8016 Error Messages

PIN EXPIRED

If you have been enrolled in the system and you are logging in for the first time you will be required to change your PIN. If all user’s PINs are forced to change you will also be required to change your PIN. In either case, respond to the PIN Expired message as follows:
1. Select
OK when you receive the message that your PIN is expired and you must change your PIN.
2. Enter your current PIN. Press DOWN.
3. Enter your new PIN. Press DOWN.
4. Confirm your new PIN. Press DOWN.
5. Enter a new duress PIN. Press DOWN.
6. Confirm the new duress PIN. Press DOWN
7. Select
save.
8. Select
YES to confirm.
9. Continue with whatever procedure you were originally logging in to perform.

Invalid PIN or User

The PIN entered does not match the user number or the user number is not enrolled. Reenter the PIN. If the PIN is lost, use the Edit Users procedure to set a temporary PIN.

Delay in Effect

A delay is still counting down. Wait until the delay has expired, then try again.

Timelocked

The door you are attempting to access is unavailable due to timelock. Wait until the door is out of timelock or use Armored Car override.

VIOLATION Close Door

1. The door has been left open until the alarm time is reached. A constant audible tone alerts you to close the door.
2. The door is sensed open, but was not opened by procedure.
3. Door sensor failure (alarming with door shut). In the first or second case simply close the door. In the third case contact NKL Technical Service immediately.

Validator Full

The validator mechanism senses that its cassette is full. Make a bank deposit (empty the bill cassette). This may require your armored car service.
Copyright ©2009